How to remove ID

In my System Requirement(IBM Rational Doors generated Microsoft Word document)ID is displaying like
ID : Sys_Req1
I want to display only Sys_Req1. Is there any option to remove the ID?

Thanks in advance
SystemAdmin - Fri Sep 16 06:37:56 EDT 2011

Re: How to remove ID
lahines - Fri Sep 16 07:09:00 EDT 2011

Your Microsoft Word export contains all the columns visible on the screen at the time of the export. Remove the Object Identifier (ID) column (right click-Remove) from the view to remove from the export.

Re: How to remove ID
SystemAdmin - Mon Sep 19 06:47:21 EDT 2011

I want to remove only ID:,I want to display Sys_req1.
For ex:
Sys_Req1 Introduction
Sys_req2 Purpose of this project

But in my case its displaying like
1 Introduction
ID : Sys_Req1

Re: How to remove ID
SystemAdmin - Mon Sep 19 08:15:11 EDT 2011

SystemAdmin - Mon Sep 19 06:47:21 EDT 2011
I want to remove only ID:,I want to display Sys_req1.
For ex:
Sys_Req1 Introduction
Sys_req2 Purpose of this project

But in my case its displaying like
1 Introduction
ID : Sys_Req1

The easiest way to deal with this is to run a Word macro after the export to replace ^pID : with ^p

Re: How to remove ID
SystemAdmin - Mon Sep 19 08:15:19 EDT 2011

SystemAdmin - Mon Sep 19 06:47:21 EDT 2011
I want to remove only ID:,I want to display Sys_req1.
For ex:
Sys_Req1 Introduction
Sys_req2 Purpose of this project

But in my case its displaying like
1 Introduction
ID : Sys_Req1

The easiest way to deal with this is to run a Word macro after the export to replace ^pID : with ^p

Re: How to remove ID
SystemAdmin - Mon Sep 19 11:19:07 EDT 2011

Another approach is to Export using Word Table format. The ID and Requirements columns will look the same as they do in DOORS.

Re: How to remove ID
SystemAdmin - Tue Sep 20 01:28:17 EDT 2011

SystemAdmin - Mon Sep 19 08:15:19 EDT 2011
The easiest way to deal with this is to run a Word macro after the export to replace ^pID : with ^p

Hi hazelw, Thanks for your reply.But am not understanding what i have to do here.You mean i have remove all ID's manually?.I am very new to doors.

Re: How to remove ID
SystemAdmin - Tue Sep 20 04:15:02 EDT 2011

SystemAdmin - Tue Sep 20 01:28:17 EDT 2011
Hi hazelw, Thanks for your reply.But am not understanding what i have to do here.You mean i have remove all ID's manually?.I am very new to doors.

In DOORS you just need to ensure that the columns are in the correct order so that you get the ID before the requirement.

When the requirements get to Word they look like this
ID : Sys_Req1
1 Introduction
ID : Sys_Req2
This document describes the system....
Record a macro in Word and use the Word search and replace to replace the 'ID :' with nothing, this is often easier if you include the preceding paragraph mark (^p). Select the replace all option.

When I have done this in the past I have also included some formatting in the search and replace macro. You can then save the Word macro in the Word template and next time you export use this template and the macro will be there ready for use.

Re: How to remove ID
SystemAdmin - Tue Sep 20 07:26:38 EDT 2011

SystemAdmin - Tue Sep 20 04:15:02 EDT 2011
In DOORS you just need to ensure that the columns are in the correct order so that you get the ID before the requirement.

When the requirements get to Word they look like this
ID : Sys_Req1
1 Introduction
ID : Sys_Req2
This document describes the system....
Record a macro in Word and use the Word search and replace to replace the 'ID :' with nothing, this is often easier if you include the preceding paragraph mark (^p). Select the replace all option.

When I have done this in the past I have also included some formatting in the search and replace macro. You can then save the Word macro in the Word template and next time you export use this template and the macro will be there ready for use.

Thanks a lot Hazelw.I tried that, its coming.But we cant do it in Doors while exporting rite?(Here am exporting from Doors to Microsoft word).After exporting into Microsoft word only we can replace that correct?.

Column ordering still has same problem.In my case column is displaying in Doors like
1st ID
2nd System Requirements
3rd Object Type

But in Microsoft word
1 Introduction
ID : Sys_Req1
Object Type : Header

I tried with moving one another i.e Object Type is first next ID etc.But no change in display order.For all case its coming same.

Re: How to remove ID
lahines - Tue Sep 20 09:36:42 EDT 2011

You indicate you are new to DOORS. A couple of suggestions.
1. If you use the Object ID to number requirements, the requirements numbers are unique but will eventually get out of order e.g., requirement 4072 will follow requirement 1.
2. It is not a good practice to call object text that is not a requirement, a requirement.
3. I suggest you
a. Create an attribute such as "RID" for Requirement ID.
b. Filter for objects that are requirements,
c. Export view Object ID and RID to a CSV spread sheet.
d. Fill from 1 to n where N is the number of requirements
e. Fill a second column with "Sys-Req ".
f. Concatenate the two columns
g. Import the result into DOORS.
h. Export this column instead of the object ID column when exporting to Word.

Re: How to remove ID
llandale - Tue Sep 20 16:30:51 EDT 2011

lahines - Tue Sep 20 09:36:42 EDT 2011
You indicate you are new to DOORS. A couple of suggestions.
1. If you use the Object ID to number requirements, the requirements numbers are unique but will eventually get out of order e.g., requirement 4072 will follow requirement 1.
2. It is not a good practice to call object text that is not a requirement, a requirement.
3. I suggest you
a. Create an attribute such as "RID" for Requirement ID.
b. Filter for objects that are requirements,
c. Export view Object ID and RID to a CSV spread sheet.
d. Fill from 1 to n where N is the number of requirements
e. Fill a second column with "Sys-Req ".
f. Concatenate the two columns
g. Import the result into DOORS.
h. Export this column instead of the object ID column when exporting to Word.

Minority opinion:

If you figure to create your requirements in DOORS, these requirments have no Identifier outside DOORS before they were created, you never figure to re-host the specifications outside DOORS, you will not be trusted down-loads of exports from classified to unclassified, and you have control and discipline to prevent folks from purging old requirements, then the Object-ID is a reasonable choice to duplicate as "Requirement ID". And its easy.

If any of the above are not met then you should manage your own "Requirement IDs", which can be tricky.

Methodologically it is unsound to use Obj ID, similar to assigning "Customer Number" based on the user's telephone. The Object purge issue likens to a user getting a new telephone, or heaven forbid that telephone number is re-used by someone else who becomes a customer.

  • Louie

Re: How to remove ID
SystemAdmin - Fri Sep 23 00:37:07 EDT 2011

Thanks everybody